Disclaimer
As Solutia's new DESIGN and COLOR system incorporates minimum 30 gage interlayer PVB, we are confident in stating that it passes standard ASTM/ANSI/CPSC standards when the same nominal thickness is used.
Applicable Standards
American Society for Testing & Materials (ASTM)
- ASTM C1036 - Standard Specification for Flat Glass
- ASTM C1048 - Standard Specification for Heat-Treated Flat Glass -
Kind HS, Kind FT Coated and Uncoated Glass
- ASTM C 1172 - Standard Specification for Laminated Architectural
Flat Glass
Interlayer Color | Thickness in (mm) | Max. width in (m) |
Clear | 0.015 (0.38) 0.030 (0.76) 0.060 (1.52) | 126 (3.2) 126 (3.2) 126 (3.2) |
Mass pigmented | 0.015 (0.38) 0.030 (0.76) | 126 (3.2) 126 (3.2) |
- ASTM E90 - Laboratory Measurement of Airborne Sound Transmission
Loss of Building Partitions and Elements
- ASTM E413 - Rating Sound Insulation
- ASTM E1332 - Standard Classification for Determination of
Outdoor-Indoor Transmission Class
- ASTM E1300 - Standard Practice for Determining the Minimum
Thickness and Type of Glass Required to Resist a Specified Load
- ASTM E1886 & E1996 - Standard Test Method and Specification for Windborne Debris
- ASTM F1233 - Standard Test Method for Security Glazing Materials
and Systems
American National Standards Institute (ANSI)
- ANSI Z97.1 - Standard for Glazing Materials Used in Buildings -
Safety Performance Specifications and Methods of Test
Consumer Products Safety Commission (CPSC)
Glass Association of North America (GANA)
- GANA - Laminated Glass Design Guide
National Security Agency (NSA)
- NSA 65-8 - Specification for RF Shielded Enclosures
Underwriters Laboratories, Inc., (UL)
- UL 972 - Burglary Resistant Glazing
- UL 752 - Bullet Resistant Equipment
Approvals
The Consumer Product Safety Commission (CPSC) and the architectural glazing safety sections of model building codes have set uniform requirements for the performance of glazing materials. Two-ply laminated glass with 0.015 in. (0.38 mm) thick Solutia's PVB based interlayer typically meets requirements for Category I, two-ply laminated glass with 0.030" (0.76 mm) thick Solutia's PVB based interlayer typically meets requirements for Category II.
Laminated glass with Solutia's PVB based interlayer meets requirements for ASTM F1233 Forced Entry Testing and UL 972.
Solutia's PVB based interlayers are approved for use in Dade County, Florida and have been issued as NOA#98-0728.05 and NOA#99-1227.02.
Environmental Considerations
Use of laminated glass can reduce heating and cooling costs. Sound
attenuation applications mean reductions in noise pollution.
Back to top
|